Operation and Setting
RECORD CONTROL
To configure a new control, keep the button (ON/OFF) on the cover pressed for 5 seconds. equipment, then FIRST
press the ON button of the remote control you want to configure and then press the OFF button on the same
control, wait 10 seconds, perform the test by pressing the buttons on the control, and watch the output trigger to
verify successful configuration.
NOTE. If the control is misconfigured or presents any configuration or operation error, reset the equipment as
described in step below, then proceed with the settings in step above.
ERASE CONTROL/RESET
Press the (ON/OFF) button located on the equipment cover for 10 seconds, then wait 10 seconds for the module
to complete the reset.
To verify the success of the procedure, press the buttons on the remote control, and make sure that the reflectors
connected to the output of the equipment will not activate.
Dimension
MONOCHROMATIC MINI LIGHT 60W
Controlador de Luces Led Monocolor
POWER
ALIMENTACIÓN
100 ~ 240 Vac
8
Installation and User's Guide
ON/OFF
OUTPUT
SALIDA
12 Vdc
- +
180mm
218mm