Descargar Imprimir esta página

HT Italia HP03010C Manual De Instrucciones página 39

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 48
5.7. CAPACITANCE MEASUREMENT
Before carrying out capacitance measurements on circuits or capacitors, cut
off power supply from the circuit being tested and let all capacitance in it be
discharged.
Fig. 9: Use of the instrument for capacitance measurement
1. Select the position 
2. Press the MODE key until the symbol "nF" is displayed.
3. Insert the red cable into input terminal VHz%
terminal COM
4. Position the test leads in the desired points of the circuit to be measured (see Fig. 9).
The display shows the value of capacitance.
5. If the symbol "O.L" is displayed, this indicates overload status.
6. For use the HOLD and RANGE functions, please refer to § 4.2.
CAUTION
EN – 14
and the black cable into input
HT3013

Publicidad

loading

Este manual también es adecuado para:

Ht3013