Porta Quick Oil Changer — Model 17800-Series
FEATURES
Pump Body:
Impeller:
Shaft Seal:
Motor:
Container:
Power Cord:
Suction Hose:
Dimensions:
Weight:
OPERATING INSTRUCTIONS
1. Run the engine approximately 5 minutes to heat oil (mini-
mum oil temperature 140°F (60ºC); maximum 185°F (85ºC),
then shut off engine prior to oil removal.
2. Push the 1/2" (13mm) suction hose onto the pump inlet hose
fitting. Position one hose clamp on the end and tighten to
secure the hose to the hose barb.
3. If using the 1/4" (6mm) dipstick probe (instead of the Female
Garden Hose Connector), insert the probe into the 1/4" x 1/2"
(6mm x 13mm), approximately 1" (25mm) long, rubber
bushing until the end of the probe and the bushing are flush
with each other. Slide the hose clamp over the end of the 1/2"
(13mm) hose and position the end of the plastic probe, with
bushing attached, in the end of the suction hose. Slide the
hose clamp to a position where it will be approximately cen-
tered over the probe/ hose bushing, and with a pair of pliers,
squeeze it together very tightly to affect a positive airtight seal.
If using the Female Garden Hose Fitting, install it onto the end
of the 1/2" (13mm) suction hose by inserting the 1/2" (13mm)
barb fitting into the hose and
secure it by screwing together the
two halves of the plastic clamp
on the hose at the position of
the barb.
4. Clamp the power cord alligator
clips (red to positive and black to
negative) to the terminals of an
appropriate voltage battery.
NOTICE: Failure to use proper size fuse in power cord fuse
holder may cause motor damage and void warranty.
Bronze construction
Nitrile (oil resistant)
Lip Type
Reversible with integral reversing
switch
Plastic with 14Qts (13.2L) capacity
8ft. (2.4m) with alligator clips
4ft. (1.2m) of neoprene hose with
40" (1m) Teflon* dipstick probe
13-1/2" (343mm) diameter
13-5/8" (354mm) high
9 lbs. (4.1 kg)
Model
Number
17800-2000
WARNING: Explosion hazard
Do not use pump for pumping gasoline or
other flammable liquids with flash point
below 100°F (37.8°C). Doing so may result in explosion which
could cause personal injury, death or property damage.
WARNING: Explosion hazard
Motor switch must be in "OFF" position
when connecting and disconnecting
alligator clips to battery terminal and ground. The switch
in an "ON" position can cause an electrical spark which can
result in explosion. Injury or death can occur.
WARNING: Explosion hazard
Take necessary precautions to ventilate
area around battery of potentially
explosive gases. Continue ventilation during oil changing
procedure. Failure to do so can result in explosion which
could cause personal injury, death or property damage.
5. If using the 1/4" (6mm) dipstick probe, insert it into the dip-
stick tube until it hits the bottom of the pan. If it is not obvious
when the probe hits the bottom of the pan, it may be helpful
to measure the distance from the top of the dipstick tube to
the bottom of the pan and mark this length on the probe with
a piece of tape. Once the probe has hit the bottom of the pan,
pull it back up about 1/8" (3mm) - 1/4" (6mm) and hold the
probe in that position or secure it with some tape during the
oil removal process.
NOTICE: Do not push the dipstick probe too far into the engine
or it may get caught on internal components and cause a
problem when removing.
If using the Female Garden Hose Fitting, simply screw it onto
the Male Garden Hose Thread, when provided, on the top of
the dipstick tube until it is tight enough to ensure an airtight
seal. It is important, when using this method, that the hose
washer in the garden hose fitting is pliable and in good
2
Amp
Voltage
Draw
12
7
Fuse
Size
10