Descargar Imprimir esta página

Chamberlain SECURITY+ 3112E FS2 Manual Del Propietário página 27

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION STEP 11
Connect Door Arm to Trolley
Follow instructions which apply to your door type as
illustrated below and on the following page.
SECTIONAL DOORS ONLY
• Make sure garage door is fully closed. Pull the
emergency release handle to disconnect the outer
trolley from the inner trolley. Slide the outer trolley
back (away from the door) about 5 cm as shown in
Figures 1, 2 and 3.
• Figure 1:
– Fasten straight door arm section to outer trolley
with the 5/16"x1" clevis pin. Secure the
connection with a ring fastener.
– Fasten curved section to the door bracket in the
same way, using the 5/16"x1-1/4" clevis pin.
• Figure 2:
– Bring arm sections together. Find two pairs of
holes that line up and join sections. Select holes
as far apart as possible to increase door arm
rigidity.
• Figure 3, Hole alignment alternative:
– If holes in curved arm are above holes in straight
arm, disconnect straight arm. Cut about 15 cm
from the solid end. Reconnect to trolley with cut
end down as shown.
– Bring arm sections together.
– Find two pairs of holes that line up and join with
bolts, lock washers and nuts.
• Proceed to Adjustment Step 1, page 29. Trolley will
re-engage automatically when opener is operated.
HARDWARE SHOWN ACTUAL SIZE
Nut 5/16"-18
Lock Washer 5/16"
Clevis Pin
5/16"x1" (Trolley)
Ring Fastener
Clevis Pin
Hex Bolt
5/16"x1-1/4"
5/16"-18x7/8"
(Door Bracket)
Outer Trolley
Ring
Fastener
Door
Bracket
Figure 1
Nuts
5/16"-18
Door Bracket
Figure 2
Nuts
5/16"-18
Figure 3
27
Inner Trolley
Straight
Door Arm
Curved
Door Arm
Clevis Pin
5/16"x1-1/4"
Lock
Washers
5/16"
Emergency
Release
Handle
Bolts
5/16"-18x7/8"
Lock
Washers
5/16"
Bolts
5/16"-18x7/8"
Cut This End
Clevis Pin
5/16"x1"

Publicidad

loading

Este manual también es adecuado para:

Security+ 3122e fs2