Operating manual
2. Gysflash configuration:
Turn on all the Gysflash units. For each Gysflash, open the Multi-charger menu (see Gysflash manual) and select
the appropriate configuration:
LCD
Multi-chargers
Parallel
3. Cable calibration
On the Gysflash Master inter face, go to the Cable calibration menu (see Gysflash manual).
Cables can be calibrated either automatically (recommended) or manually (OLED screen only).
This procedure is used to calibrate the charging cables of the unit, so that the Gysflash can compensate
effectively for any drop in voltage caused by the cables.
LCD
Cable calibration:
11.40 / 5.50 mohm
GYSFLASH 1
Master
GYSFLASH 2
Slave 1
GYSFLASH 3
Slave 2
GYSFLASH 4
Slave 3
Usage
Switch on all Gysflash units
1
2
Check that the Gysflash units are correctly connected to the SHM and PHM (Installation section).
Use the Gysflash Master interface to con trol the multi-charger.
3
14
Translation of the original
instructions
OLED
Multi-charger
Parallel
2 c h a rg er s
x2
OLED
R_master
+
-
R_slave 1
+
-
PHM
R_slave 2
+
-
R_slave 3
+
-
For each charger, select «Parallel», as well
as the number of chargers you wish to use
in parallel.
- Automatic calibration (recommended)
To do the calibration, simply short-circuit
the PHM output clamps and then confirm.
The device automatically calculates the
cable resistance, and displays the differ-
ent resistance values for each compo-
nent of the installation on the screen.
- Manual calibration (not recommended)
The resistance values of the cables can be
set manually.
R_common
+
-
SMART HUB MODULE