This guide presents the basic steps to set up and operate this device.
For the user manual and specifications, visit intellinet-network.com.
Register your product at register.intellinet-network.com/r/561969
or scan the QR code on the cover.
Placement
Prior to use, it is recommended that the switch be placed/positioned:
• on a level surface that can support the
weight of the switch (and any other
items that need to be considered);
• with a minimum of 25 mm
(approx. 1") of clearance
on the top and sides for adequate ventilation;
• away from sources of electrical noise: radios,
transmitters, broadband amplifiers, etc.;
• where it cannot be affected by excessive moisture;
• within 100 m (approx. 328') of network devices it's to be connected to.
The switch includes brackets and screws for optional rack mounting.
1 Disconnect any cables from the switch.
2 Position a bracket over the mounting
holes on one side of the switch and
secure it in place with screws.
3 Repeat Step 2 on the other side of the switch.
4 Position the switch in the rack and
screw the brackets to the rack.
5 Reconnect any cables.
Chassis Ground Column
Located on the side of the power supply connector, a grounding terminal
connector is used to provide proper grounding for your Intellinet Network
Solutions switch. If you use the chassis grounding screw, it should be
wired to an object that provides earth ground. In rackmount installations,
grounding is typically provided by the metal frame of the mounting rack.
2
English
Instructions