6.15. Make sure the burn pot is correctly placed, that it is in contact with the resistance tube and the central hole
of the burn pot goes along with this tube.

Burn pot.

Resistance air inlet.

Resistance drive.

Start-up resistance.

Resistance tube support.

Screw of resistance.

Resistance support guide.

Resistance support tube, badly fixed.

Resistance support tube, badly fixed.

Start-up resistance, badly fixed.

Resistance support tube; badly fixed.
6.16. Pay special attention to the cleaning of the stove as excess of dust may prevent the stove from starting on.
THE START-UP RESISTANCE DOES NOT WORK:
6.17. Make sure the resistance heats, take the burn pot and see if it becomes
THE GAS OUTLET EXTRACTOR DOES NOT WORK OR DOES NOT WORK CORRECTLY:
6.18. Make sure the motor rotates properly by rotating it with your hand (the stove should be disconnected to do
so).
6.19. Check that power reaches the motor, by
6.20. Also check the exhaust connection strip and the C.P.U.
THE CONVECTION FAN DOES NOT ROTATE:
6.21. Make sure that the turbine is not stalled by unplugging the stove. Then access to the right side and rotate i
with your hand to ensure that it rotates perfectly.
THE STOVE TURNS OFF:
6.22. There might be no pellets in the stove.
6.23. A forgotten set programm e might have stopped the stove.
6.24. A bad quality of pellets, humidity can be causes of unexpected stops.
6.25. If the stove turns off and there are half burnt pellets in the burn pot, this might be due to a lack of cleaning.
Revise chapter related to cleaning and maintenance.
6.26. Internal dirt or ongoing use without cleaning.
6.27. If the stove is off and t here are no pellets in the burn pot, check the reducer motor, convection motor and
extractor.
ALARM IN WiFi APPLIANCE/KEYBOARD:
Review section 5 (Alarms)
turning the stove on.
65
Drawing 42
light red ( d o not touch).

Publicidad

loading