STORING UNIT
SHORT TERM (1-6 MONTHS):
1. Add fuel conditioner & stabilizer at the specified concentration.
2. Run the unit for two (2) minutes to ensure the mixed fuel is in the entire fuel
system. Close the fuel valve and run the unit until it stops.
3. For Gasoline Engines: Remove the spark plug, pour 1-2 teaspoons (5-10cc)
of engine oil into the cylinder, slowly pull the starter handle 2 or 3 times,
reinstall the spark plug and tighten securely.
4. Clean the exterior surface of the unit and apply a rust inhibitor.
5. Store the unit in a dry, well ventilated place.
LONG TERM (MORE THAN 6 MONTHS):
1. Add fuel conditioner & stabilizer at the specified concentration.
2. Run the unit until the fuel tank and carburetor are dry. As the engine is
beginning to die, move the choke lever to the choke position.
NOTE: Turn off the idle control to decrease the run time.
3. For Gasoline Engines: Remove the spark plug, pour 1-2 teaspoons (5-10cc)
of engine oil into the cylinder, slowly pull the starter handle 2 or 3 times,
reinstall the spark plug and tighten securely.
4. Clean the exterior surface of the unit and apply a rust inhibitor.
5. Store the unit in a dry, well ventilated place.
WARNING: FUEL SHOULD BE DRAINED IN A WELL VENTILATED
AREA AND STORED IN AN APPROVED CONTAINER.
Operator's Manual
STORAGE
27