INSTALLATION
TL 16 refrigerators have been designed and constructed exclusively for recessed installation and installation that is in
compliance with standard dimensions. The refrigerator must always be in a horizontal position, with the compressor's rubber
feet at the bottom. The compressor is capable of functioning at angles of up to 30°. The compressor can become damaged
with any higher inclinations. Also remote operation compressors must be installed with its rubber feet downward.
The product should be secured to the lodgings using the Easy Fix fastening system, which are special pre-drilled fastening
points inside the trunk for easy, effective installation that is not visible from the outside.
Where Easy Fix fastening cannot be used, you can however install the refrigerator by fastening it using mounting flanges
(optional) on 3 or 4 sides.
Always secure the refrigerator in such a way so that it will not tip/slide forward when the drawer is opened or in the case of
sudden vehicle movement. The unit should be anchored by at least 2 fastening points, in accordance with the provisions of
the EN 60335-2-24 standard.
30
Drill the fastening point with a drill or sharp tool (A, only
requires light pressure as it is a pre-drilled area). Screw in
and fasten the trunk from inside with M4x16 screws (B) and
take care to re-insert the cover complete with insulation
foam to ensure continued correct product insulation ( C+D).
TL16 OFF_(DC)_IM_31-01-2022