VENTILATION
It is extremely important for the compressor/condensing unit located behind the refrigerator to be well ventilated so that the
fresh air can enter at the bottom and pass behind the refrigerator, with the hot air being allowed to escape from the top or
sides.
The illustration shows an example of how the refrigerator housing should be set.
ELECTRICAL CONNECTIONS
- In order connect the unit to the vehicle's electrical system, proceed as follows:
- Before turning on the appliance, check to make sure that the voltage of the electrical system and/or battery complies with
that which is indicated on the unit's data plate.
- Connect the refrigerator directly to the battery or to the relative main switch and make sure that the system is equipped
with an electric device that's capable of protecting the circuit against possible overcurrents.
If the power supply voltage is different from 12/24 Vdc, install a ΔI 0.03 A differential circuit breaker. Avoid connecting the unit
via the vehicle's control panel as this could result in voltage drops.
- The product is supplied with a 10 A fuse. A separate switch that simultaneously disconnects the power cables must be
installed upstream from the refrigerator. Check to make sure that this switch supports the 10 A current load.
WARNING
If there is a battery charger, it must be connected to the battery and never directly to the refrigerator..