Application
Single-hole mixer suitable for:
• direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Operation with unpressurised storage heaters
(= displacement water heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
• Max. flow:
1.9 L/min or 0.5 gpm/0.41 MPa (60 psi)
• Flow pressure
- min.
- recommended
0.1 - 0.5 MPa (14.5 - 72.5 psi)
- greater than 0.5 MPa (72.5 psi), fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range according to Kodak Gray Card, grey side,
8x10", landscape (factory setting):
• Type of fitting protection:
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Additional instructions regarding programme
overview, programme selection and activation of
the functions can be downloaded under
www.grohe.com/tpi/euroeco-ce.
Special accessories
Further settings and special functions are available
via the infrared remote control (Prod. No. 36 206).
1
English
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawing and Fig. [1] on fold-out page I.
Fasten fitting to wash basin, see Figs. [2] and [3].
Connection
1. Attach solenoid valve (A) to nipple (B), assemble two-piece
clip (C) at the connection point and engage, see Fig. [4].
2. Attach solenoid valve (A) to the connection hose,
see Fig. [5].
3. Connect adapter (D) to the service valve, see fold-out
page II, Fig. [6].
4. Install filter (E) in nipple (B), see Fig. [7].
5. Install solenoid valve (A) via nipple (B) on the adapter (D),
0.05 MPa (7.25 psi)
ensuring that no installation forces are applied to the
solenoid valve.
6. Connect solenoid valve cable (A1) to electronics cable (F1),
1 MPa (145 psi)
see Fig. [8].
1.6 MPa (232 psi)
Connecting the voltage supply
158 °F
1. Secure bracket (G1) using screws and plugs, see Fig. [9].
2. Insert battery (G2) in battery housing (G4) and fit lid (G3).
60 s
Observe correct polarity.
1 s
3. Connect plug-in connector between electronics cable (F2)
and battery housing (G), see Fig. [10].
approx. 5"
4. Engage battery housing (G) in bracket (G1).
IP 59 K
Open hot and cold water supply and check connections
for watertightness.
activatable
readable
Operation
The infrared electronics emit invisible, pulsed light.
activatable
The sensor system is adjusted so that water flow is
deactivated
initiated when the hands approach the vicinity of the spout.
3.5 min
When the hands are withdrawn from the vicinity of the
spout, water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.