Maintenance
Shut off the water supply and switch off the voltage
supply.
Inspect and clean all components and replace if necessary.
I. Battery
Batteries which are almost discharged are indicated
by a flashing indicator lamp in the sensor system.
1. Pull battery housing (G) out of bracket (G1) and detach
electronics cable (F2), see fold-out page II, Fig. [11].
2. Remove lid (G3) of battery housing (G), as shown
in Fig. [11].
3. Remove battery (G2) and replace.
Assemble in reverse order.
II. Solenoid valve
1. Disconnect plug-in connector between the electronics
and solenoid valve (A), see fold-out page II, Fig. [12].
2. Unscrew the hose union nut from solenoid valve (A).
3. Unscrew nipple (B) from the adapter and replace solenoid
valve (A), see Fig. [13].
For installation, see section Installation.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
• No voltage
- Battery discharged
- Plug-in connector without contact
• Hands not in detection zone
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water flow
• Sensor system detection zone
set too high for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filter in connection hose dirty
• Shut-off valve, service valve not fully
open
• Water supply restricted
English
III. Filter
1. Unscrew nipple (B) from the adapter, see fold-out page II,
Fig. [14].
2. Remove filter (E) and clean or replace.
Assemble in reverse order.
Replacement parts, see fold-out page I
(* = special accessories).
Care
For directions on the care of this fitting, please refer
to the accompanying Care Instructions.
Disposal note
Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valve, service valve
- Clean or replace filter
- Replace solenoid valve
- Attach plug-in connector
- Replace battery
- Check plug-in connectors
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control
(special accessory, Prod. No.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean or replace filter
- Replace connection hose
- Fully open shut-off valve, service valve
- Check supply lines, open shut-off valve,
service valve
2