• OPERATING INSTRUCTIONS
_Set
to the highest temperature
in manual COOL mode,
and operate for 3 to 4 hours.
• This dries the inside of the unit.
• Moisture in the air conditioner
contributes
to favorable
conditions
for
growth of fungi, such as mold.
OON/OFF
......... Press _
to stop the operation.
_Turn
off the breaker and/or disconnect the power sup-
ply plug.
_
Remove all batteries from the remote controller.
When
using the air conditioner
again:
Clean the air filter.
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
Check that the ground is connected correctly.
Refer to the "PREPARATION
BEFORE OPERATION",
and follow the instructions. |
Installation
place
Avoid installing
the air conditioner
in the following
places.
,
Where there is much machine oil.
,
Salty places such as the seaside.
,
Where sulfide gas is generated
such as a hot spring.
,
Where oil is splashed or where the area is filled with oily smoke (such as cook-
ing areas and factories,
in which the properties
of plastic could be changed
and damaged).
,
Where there is high-frequency
or wireless equipment.
,
Where the air from the outdoor unit air outlet is blocked.
,
Where the operation
sound or air from the outdoor unit does not bother the
house next door.
sets,
radios,
etc.
In areas
where
the reception
is weak,
provide
greater
space
between
the outdoor
unit
and
the
antentla
of the affected
device
if operation
of the air
I
II
\\
X_
]the
noi .........
_"
FH15.
18)
_/'//'{
I
j
LOt more
\\
\x'vl
TV
\ /
. _.1
!fTraq
(200/500
mm)
[-/'/A
I
_
\\
3f_{I
m) zJ
%1
/
--
*_
IIIIII
Ior
more
V/A
Electrical
work
,
Provide an exclusive
circuit for the power supply of the air conditioner.
,
Be sure to observe the breaker capacity.
If you have any questions,
consult
your dealer.
Guaranteed
operating range
_i_i,_i
¸:!_!_i_!:_!_i_iii:_!i_i_i_i_i_i_i!i_i_i_i_i_!i_!!i_i_!_!_!_!_i!_i!_!;_!_!_!i_!_i_i_i_i_i_i_i_i_iiiii_i_!!
Upper limit
90°F (32.2°C) DB
115°F (46.1°C) DB
73°F (22.8°C) WB
Cooling
Lower limit
67°F (19.4°C) DB
14°F (-10°C) DB
57°F (13.9°C) WB
Upper limit
80°F (26.7°C) DB
75°F (23.9°C) DB
--
65°F (18.3°C) WB
Heating
Lower limit
70°F (21.1°C) DB
-13°F (-25°C) DB
--
-14°F (-25.6°C)
WB
DB: Dry Bulb
WB: Wet Bulb
Note:
1. The guaranteed
operating range value is for 1:1 System Application.
2. If the outdoor temperature
is below the lower limit of guaranteed
operating
range, the outdoor unit may
stop operation until the outdoor temperature
exceeds the lower limit.
En-13