float. In addition, a second stop float of the entire system can be configured for double safety
(this option can be easily enabled from the application fine settings menu).
9.3) Installation as a BOREHOLE PUMP system
It allows the starting of a well pump through a pressure switch signal, level float switch, tank
probes, pressure transducer or by time programming. To protect the pump from dry running, it
is possible to use 2 or 3 probes in the well or also install a float switch. In this case, although it
is not usual, the system could operate in a tank with 2 well pumps in which alternating start-up
or joint operation is required, as if it were a pressure group of surface pumps.
9.4) COMBINED installation (only available in the device for 2 pumps)
It allows the start/stop of 2 pumps completely independent of each other, as described in the
heading of this section of the manual. The protections of the pumps against dry work, phase
consumption anomaly, etc... are independently configurable for each pump, being able to
enable/disable these functions in 1 of the pumps, in the 2 or in none of them, at choice of the
user. In this type of application, the start/stop through the irrigation controller signal will only
work for pump 2.
10. STANDARD SETTINGS AND CONNECTIONS
The following diagrams show the standard configuration according to the type of application,
both at the device configuration level and at the connection level of the pump maneuvering
and protection elements.
10.1) 1 pump device:
BOOSTER SET
• Language
• Time and date
• Pump amperage
• Application: BOOSTER SET
• Start/Stop device: PRESSURE SWITCH
• Protection device: FLOAT SWITCH
35