Operation Control And Description; Installation, Debugging And Operation - gala gar ATLANTIC 180 Manual Técnico De Instrucciones

Quipos inverter de soldadura al arco
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. OPERATION CONTROL AND DESCRIPTION

1. Overheating
Overheating LED on indicates that the temperature
inside the machine is too high and the machine is under
overheating protection status.
2. Power LED: To indicate the power. Power LED on
indicates that the power switch of the machine is on.
3. MMA/TIG switch: To toggle between MMA and TIG.
4. "+" output terminal: To connect the electrode holder.
5. "-" output terminal: To connect the work clamp.
6. Trademark
7. Welding current knob: To adjust the output current.
8. Handle
9. Power switch: Power ON/OFF switch.
10. Warning sign
11. Power input: power input cable
12. Cooling fan
 INSTALLATION, DEBUGGING AND OPERATION
Note: Please install the machine strictly according to the following steps.
Turn off the power supply switch before any electric connection operation.
The housing protection grade of this machine is IP21S, so do not use it in rain.
Note: This table is suitable for mild steel welding. For other materials, consult related materials
and welding process for reference.
LED:
To
indicate
Fig.6 Schematic Diagram of MMA Welding
ATLANTIC 180/200
overheating.
1
2
3
4
9
10
11
12
Electrode Diameter (mm)
2,0
2,5
3,2
4,0
15/30
8
7
6
5
Fig. 3
Fig. 4
Recommended
Welding Current (A)
60~100
80~120
108~148
140~200

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Atlantic 20022290180ac22290202ac

Tabla de contenido