10. TROUBLESHOOTING.
The following operation requires sufficient professional knowledge on electric aspect and comprehensive safety
knowledge. Operators should be holders of valid qualification certificates which can prove their skills and
knowledge. Make sure the input cable of the machine is disconnected from the electricity utility before uncovering
the welding machine
Common Malfunction Analysis and Solution:
Malfunction Phenomena
Turn on the machine, the power
LED is off, the fan doesn't work,
and no welding output.
Turn on the machine, the fan
works, but the output current is
unstable and can't be controlled by
potentiometer when welding.
Turn on the machine, the power
LED is on, the fan works, but no
welding output.
The electrode holder becomes very
hot.
Excessive spatter in MMA welding.
This product is being improved unceasingly, so differences may appear in parts except for functions and operation.
Thanks for understanding.
ATLANTIC 180/200
Causes and Solutions
(3) Check if the power switch is closed.
(4) No input power.
(3) The current potentiometer fails. Replace it.
(4) Check if any loose contact exists inside the machine. If any,
reconnect.
(4) Check if any loose contact exists inside the machine.
(5) Open circuit or loose contact occurs at the joint of output terminal.
(6) The overheating LED is on.
a) The machine is under over-heating protection status. It can
recover automatically after the welding machine is cooled.
b) Check if the thermal switch is ok. Replace it if damaged.
c)
Check if the thermal switch is loosely connected, and
reconnect it if necessary.
The rated current of the electrode holder is smaller than its actual
working current. Replace it with a bigger rated current.
The output polarity connection is incorrect. Exchange the polarity.