Installation
INSTALLATION PLANNING
Before beginning the installation and use of the JATRHG charging station, the user must always read
this document carefully, take into account all the warnings, and follow all the instructions outlined in
this manual.
The following recommendations should be considered:
The JATRHG charging station must always be installed by qualified personnel in accordance with the
electrical regulations applicable in your country
Ensure that the charging station can be vertically installed on a solid, fire-resistant wall or on the
optional metal pole;
Ensure there is enough space for the installation of the charging station.
Ensure that the required power cable (not included) from the junction box to the charging station can
be installed in accordance with the electrical regulations applicable in your country;
Ensure that the electric vehicle can be parked near the charging station for extended periods, so that
the charging connector with an 8 m cable can be plugged into the electric vehicle's charging socket;
If an optional metal pole is used, ensure it is mounted at the highest point off the ground so that the
base of the metal pole does not sit in a puddle of water during rain.
REQUIRED TOOLS
To properly install the JATRHG charging station, the following tools are required:
CABLE REQUIREMENT
[ S1-72-8M 7kw] The minimum cable required for this charging device is 3*6mm square. The length
shall not exceed 40 meters. If more than 40 meters, please choose 3*10 mm square cable. Use at least
C40 2P circuit breaker for a 7KW charger.
[ S1-110-8M 11kw] The minimum cable required for this charging device is 5*2.5mm square. The
length shall not exceed 40 meters. If more than 40 meters, please choose 3*6 square cable. Use at least
C20 4P circuit breaker for a 11KW charger.
[ S1-220-8M 22kw] The minimum cable required for this charging device is 5*6mm square. The length
shall not exceed 40 meters. If more than 40 meters, please choose 3*10 square cable. Use at least C40
4P circuit breaker for a 22KW charger.
Check the local electrical codes regarding the need to install an external emergency shut-off switch for
the JATRHG charging station.
Due to the risk of electric shock, the electrical installation for powering the
charging station must always be performed by qualified personnel and in
accordance with the electrical regulations in force in your country.
comply could result in electric shock, which could be fatal or cause serious injuries.
6
Failure to

Publicidad