Head
EN
L1,L2,L3*
Information
31.5A*
385V
21KW*
Energy
42
CP
6.05*
PWM
63%
Current
32A
Mode
Charging
Time
02:00:00
Delay
Notification
Value
Current Software Version
Current system language. The default language is English.
Support is also available for French, German, Spanish, and
Italian.
This feature is specific to the 11kW and 22kW three-phase
models, where the system cycles through the display of
each phase every 3 seconds.
L2 and L3 have none, it indicates that your electric vehicle
supports single-phase charging only and does not support
three-phase
on the 7kW charging station models.
Current amperage;
*The current amperage may be significantly lower than the
maximum setting you select, depending on the maximum
AC current your electric vehicle can accept. For example, if
your vehicle's maximum AC charging capacity is 11 kW,
even if you use a 22 kW charging station set at 32A, the
actual current may only be around 16A. This limitation is
determined by your vehicle's charging capability and does
not indicate a malfunction of the charging station.
Current voltage;
Current power;
*In a single-phase : Power = V× I×Power Factor (cos(θ))
In a three-phase: Power=√3 ×V×I×Power Factor (cos(θ))
Current energy consumption = Current power * Usage time.
kWh*
*This value resets to zero each time the type 2 connector is
unplugged.
Voltage of control pilot.
*12V (±0.4V) Disconnected, the charging cable is not
connected to the electric vehicle's port.
9V (±0.4V) Connected. The charging cable is plugged in, but
the vehicle has not ready to start.
6V (±0.4V) Charge Ready. The charging station can start
supplying power.
Pulse Width Modulation
Rated Current
Status indicator, there are 3 modes: Standby ,
Charging and Fault
The charging time
Scheduled Charging Countdown
Notification for using.
Description
If only L1 has a current while
charging.*This display feature is not available
9