Other Provisions
The use of the compressor can cause hazards to life and limb of
the user or third parties, or damage to the compressor or other
property, if the compressor:
Is not used properly.
Is operated by untrained personnel.
Is modified or altered.
The safety instructions are not followed.
The following apply in addition to these operating instructions:
Applicable accident prevention regulations. Generally
recognized safety rules.
Country-specific regulations.
Installation Site / Altitude
The compressor is intended to be installed in a suitable compressor
room. The compressor is not suitable for outdoor installation.
Depending on the operating pressure, ambient humidity, and
ambient temperature at which the compressor is operated, the
permissible altitude of the installation site is limited. The permissible
site altitude is determined by Ingersoll Rand for each individual
case in consultation with the customer.
Pressure Equipment
A pressure safeguard (pressure relief or the like) that conforms to
the applicable specifications must be provided for the pressure
equipment and systems installed in the compressed air supply
network, considering the weakest pressurized component.
Work Environment
The lighting intensity in the area of the compressor must be ≥ 200 lx
in normal operation.
The lighting intensity must be ≥ 500 lx for inspection and
maintenance work.
The ambient temperature for operation.
EN-4
RELEASED 02/Nov/2023 21:18:09 GMT
1.4
Incorrect Usage and Abuse
The following rationally foreseeable applications (incorrect usage)
do not comply with the intended use:
Limitations on Use
Operation of the compressor is not permitted:
FORESEEABLE MISUSE
Compressing gases other than atmospheric air.
Operation outside of the permissible operating limits, even
if exceeded for only a short time, or if not immediately
detectable.
Operation outside of the permissible ambient temperatures.
Intake of non-atmospheric air (over pressure or under
pressure).
Use as a respiratory air compressor.
Manipulation of sensor signals.
Changing signals from sensors.
Operation without protective and safety devices.
Operation with defective, deactivated, or manipulated
protective and safety devices, or safety valves, or operation
with other safety-related defects.
Failure to comply with maintenance intervals.
Failure to perform maintenance and repairs.
Incorrectly executed maintenance and repairs.
Outside of the permissible ambient temperatures.
On a foundation that does not have sufficient load capacity.
In areas with explosive atmosphere.