TROUBLESHOOTING
PNEUMATIC TOOL/COMPRESSOR PROBLEMS
PROBLEM
COMPRESSOR
WON'T START
LOW PRESSURE
OIL IN DISCHARGE
COMPRESSOR
OVERHEATS
CAUSE
On/Off switch in OFF position
On/Off switch in OFF position
Choke lever in Open Choke
(running) position
Fuel tank empty
Spark plug fouled
Motor air filter plugged
Other
Drain cock open or loose
Safety relief valve leaks
Open or broken unloader valve
Dirty or plugged air filter
Air fitting on hose stuck open
Improper oil viscosity
Too much oil in crankcase
Compressor overheated
Restricted air filter
Worn piston rings
Clogged inlet filter
Dirty compressor, head, cylinder,
or intercooler
Operating pressure too high
Low oil level, or wrong oil used
Air tool or attachment air
consumption exceeds compressor
output - compressor run cycle
too long
28
CORRECTIVE ACTION
Move switch to ON position
Move switch to ON position
Move lever to Closed choke
(starting) position
Fill fuel tank
Replace spark plug
Replace filter
Refer to engine
manufacturer's manual
Close or tighten
Replace
Replace
Clean or replace as necessary
Repair or replace
Drain and replace oil
Drain oil to proper level
Air pressure regulated too high
Clean or replace air filter
Replace piston rings
Clean or replace as necessary
Clean with compressed air
Reduce pressure
Drain and replace oil
Reduce air consumption
requirements