D. Silence mode
Silence mode should only be used if the source of the alarm is known and
safe. Press the test button to set the silence mode. During silence mode,
the red LED light flashes once every 8 seconds. The detector is
automatically reset after 10 minutes.
CAUTION
Before using the silence mode, identify the source of the smoke and be
certain a safe condition exists.
E. Mount the detector
Determine correct mounting location
Check figure 3, 4 and 5 for correct mounting
locations. Most EU countries require smoke
detectors on all floors and escape routes.
Smoke spreads horizontally after rising to
the ceiling, so install the detector in middle
of the ceiling.
If the length of the room or the hall is
beyond 10 meters, you need to install
multiple alarms.
Do not mount detector on these locations
Areas with high-humidity (e.g. kitchens, bathrooms), insects, dust/dirt,
easily polluted and high-temperature.
Within 1.5 meters of lamps, next to air outlets (e.g. doors/windows),
fans and central heating.
In top of room with sloping roofs, in the corner of the room or other
dead-air spaces.
Places with difficult access, making it difficult to operate the test
function.
05
Figure 3: Recommended
mounting locations