After carrying out all the assembly and installation
procedures, the compressor is ready to run. The start-up
procedure should be carried out as soon as the compressor
is installed and in the following order:
1. Check the oil level sight glass (19) and plug in the power
cord;
2. Pull up the "ON/OFF" switch (16) to start the compressor
motor;
- The compressor motor will run until the tank is
completely full. When the tank reaches its maximum
pressure, set on the pressure switch (4), the motor
switches off automatically.
- As soon as the motor shuts down, the compressed air
accumulated in the discharge pipe between the
compressor pump and the check valve is released. This
is the necessary condition to prevent to motor from
restarting under stress. This prevents motor damage
and extends its service life.
3. Press down the "ON/OFF" switch to stop the motor and
prevent it from starting automatically;
4. Open the tank drain valve (11) to empty condensed water
inside the tank;
5. After all the condensed water has come out, screw the
tank drain valve;
6. Connect the air blow guns or compressed air tools to
outlet valves with quick-release coupling (14) or connect
them to fixed distribution networks;
7. Pull up the "ON/OFF" switch so that the compressor is
ready to start;
- When the compressor is switched on, if the pressure
in the air tank is lower than the minimum pressure set
on the pressure switch, the motor starts immediately.
8. Check the pipes or couplings/fittings for air leaks. If you
do not have any tools or equipment attached to the
compressor or in the distribution network and the
compressor starts up systematically, there is a leakage.
The automatic operation of the compressor is controlled by
a pressure switch (4). The compressor starts when the
minimum pressure (6 bar) is reached and stops when the
maximum pressure is reached, as long as the "ON/OFF"
switch is pulled upwards.
Do not adjust factory set pressure settings. They shall not
be changed.
The "ON/OFF" switch attached to the pressure switch
enables the compressor to be stopped whenever the user
wishes or in the event of an emergency.
The safety valve (13) is set to trip according to the permitted
pressure of the air receiver tank (2). If for some reason the
permitted tank pressure is reached and the motor does not
stop, the safety valve should open. It is not allowed to
adjust the safety valve or remove the plastic seal.