Sensor Override
Electronic
Bypass Button
Electronic Bypass
To electronically bypass the solenoid valve, push the bypass button. The red light
should flash 3 times. The faucet can now be used manually and the sensor will be
disabled.
To exit the electronic bypass, push the button again, the light will flash 6 times.
The sensor is now active, verify that the handle is open to use touchless mode.
Manual Bypass
The solenoid valve can be bypassed if the solenoid valve fails to operate properly
and cannot be electronically bypassed.
Turn OFF the water and open the handle to relieve the water pressure.
Remove the clips as shown.
Disconnect the solenoid valve.
Connect the fittings together with one of the clips that were removed.
The faucet can now be used manually.
Reconnect the solenoid valve by following these steps in reverse.
Kohler Co.
LED
15
1562954-2-B