Too many leaks in plumbing
Holes in abrasive hose
Air filter on compressor plugged
Lack of air pressure:
Compressor too small
Supply valves not on full position
Nozzle size too large
Leaks in plumbing
Holes in abrasive hose
Air filter on compressor plugged
Urethane gasket worn or dirty
Lack of abrasive flow:
Blaster tank empty
Moisture in media
Not enough air pressure
Abrasive hose kinked
Debris in media
WARNING!
Failure to observe the following before performing any maintenance could
cause serious injury or death from the sudden release of compressed air:
● Depressurize the blast machine.
● Disconnect power supply.
● Lockout and tag out the compressed air supply.
● Bleed the air supply line to the blast gun.
Immediate replacement of worn components is required.Failure to replace
Seal and tighten plumbing
Replace hose
Clean
Use smaller nozzle
Open valves
Use smaller size
Seal and tighten plumbing
Replace hose
Clean filter
Clean or replace gasket
Fill tank
Dry media
Check system
Straighten hose
Clean or screen media