545150014
SECURING THE GAS CYLINDER
1. Position a gas cylinder inside the tank housing.
2. Fasten the straps around the cylinder. Make sure they are tightened properly.
CAUTION: Do not restraint the regulator with the straps!
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas
•
tightness check must be performed at the installation site due to possible mishandling in
shipment or excessive pressure being applied to the heater.
The heater must be checked with a full cylinder.
•
Make sure the safety control valve is in the OFF position.
•
Make a soap solution of one part liquid detergent and one part water. The soap solution can
•
be applied with a spray bottle, brush or rag.
Soap bubbles will appear in case of a leak. For leakage test points see pictures below. Turn the
•
gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply
•
on and recheck. Contact your dealer for assistance if bubbles continue to appear.
ATTENTION: Never use a naked flame to test for leaks. Never leak test while smoking.
EN
8