5.2. AC live wires detection
1. Switch on the instrument by pressing the TEST key for 2s
2. Press the MODE key to select the detection of AC voltage
live wires (symbol
3. Place the instrument on the surface that encloses the object
being searched and press the TEST key in order to perform
a first calibration. A short sound, the brief lighting of the bar
and the
instrument is ready for scanning
4. Hold the instrument in the lower part and move it slowly on
the surface from left to right (see Fig.4 - left part)
5. When the central bar is shown on the display (see Fig. 4 –
middle part) the instrument emits a continuous sound. Stop
the instrument and mark the initial edge of the object on the
surface (1st marker)
6. Continue the search scan along the surface until the
graphic bar disappears and the sound stops (see Fig.4 -
middle part)
7. Stop the instrument and mark the 2nd marker on the
surface (see Fig.4 - middle part)
8. Position the instrument in the space between the 1st and
2nd marker and press the TEST key in order to perform a
second calibration
shown on the display)
symbol flashes on the display to indicate that the
Fig. 4: Scanning of AC live wires

Publicidad