Descargar Imprimir esta página

Kesser K-WIFH-425FB Manual De Instrucciones página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

12
Commissioning
Follow these instructions to get the heater up and running:
1. Check the heater to make sure it is not damaged.
2. DATE, TIME SETTING
Turn on the side switch, make sure the device is turned on, turn on the heater, press "SET" for 3
seconds to set the schedule and press "t." or "V" to set the hour from 01 -23, press "SET", the
minute code flashes, press "e." or "'7" to set the minute from 00-59. Press
"SET', the week code flashes, press "e." or "'7" to make the setting week of MO-SU, press "SET" to
save or wait 10 seconds, then will be saved automatically.
3. Power switch
Turn on the heater.
4. M switch
Press "M" to set normal mode or week mode. In normal mode, the heater is set without a
timer.
5. Temperaturschalter
Press "M", the heater is in normal mode, press "SET" to set your desired temperature with the
arrows.
6. Hours
Press "M", select the week code, the LCD display week (MO-SU) at the top and display "SET" in
the left corner, the temperature code flashes, press "t." or "'v" and set the desired
temperature, press "SET". On the screen, "ON" will appear to start the timer setting. The hour
code is flashing. Set the timer start hour. Press "t." or "'v" to make the desired
Select start hour. The minute code flashes to set the timer to the minute. Press "SET". On the
screen,
"OFF" is displayed to exit the timer setting. The hour code is flashing. Set the timer to Stop Hour.
Press "t." or
"'v". To select the desired stop hour, the minute code flashes to set the timer to the minute to
stop. The stop time must still be the start time. If the stop time is before the start time, the timer
for that date is out of function.
7. Exit timer mode
Press "M" to select the timer between the weekly timer mode and the normal mode.
8. Room temperature control with detection of open windows
The process of heating equipment in the room, open doors and windows of the room or room
ventilation system, equipment has its own assessment without heating, if the ambient
temperature is more than 3 °c, to energy
to save, heating power; If you want to continue heating, you must
Close the doors and windows and turn on the appliance so that the appliance enters the
operating state and can continue to heat.
9. Cancel window opening
When the product leaves the factory, the window feature is enabled by default. If the user
wants to cancel the window function, press the toast "'v" for 5 seconds. Release the toast "'v"
after you
have heard the sound of "di" The screen goes out and the window opening function is
successfully aborted.
10. Restore Window Function
If the user needs to use the window feature again, press the Up Arrow button for 5 seconds.
After clicking the
, release the "Add" button, the window opening icon "" in the lower right corner of the screen
will light up and the window opening function will return to normal.
11. Remote Control Instruction:
Before use, the remote control and heating must be coordinated with each other.
* In Standby/Power on mode, press and hold the power button on the LCD control panel for 3
seconds and a beep will sound.
* Then operate the remote control as described above in l - 9 steps.
www.eshopping.de
Hergestellt für Dilaw Warehouse GmbH // Fuggerstraße 15a // 48165 Münster // Germany

Publicidad

loading

Este manual también es adecuado para:

K-wifh-550fb