Descargar Imprimir esta página

Tornado OB 28/20 Manual De Operaciones Y Mantenimiento página 37

Publicidad

Insufficient Water On The Base
1. Check that the solution valve lever (1) is open.
2. Check the level of the liquid in the solution tank.
3. Check that the solution filter (2) is clean.
4. The machine is equipped with solenoid valve, therefore act upon the levers
drive control (3).
If the problem persists, please contact the authorized technical assistance.
The Machine Does Not Clean Properly
1. Verify the presence of the PAD.
2. Verify that the PAD is intact.
3. To replace the pad, see under "PAD DISASSEMBLY" and "PAD ASSEMBLY".
4. The solution detergent is insufficient: open more the solution valve.
5. Check that the liquid detergent is in the recommended percentage.
6. Increase the base pressure (see at paragraph "ADJUSTMENT OF THE BASE
PRESSURE").
Contact the authorized technical assistance for advice.
The Squeegee Does Not Dry Perfectly
1. Check that the squeegee rubbers are clean.
2. Check the adjustment of the height and the inclination of the squeegee. (see
section "ADJUSTMENT OF THE SQUEEGEE" in "BEFORE USE").
3. Check that the suction hose is correctly inserted in the proper seat on the
recovery tank.
4. Clean the suction filter.
5. Replace the rubbers if worn out.
6. Check that the suction motor switch is on.
FAULT DIAGNOSIS
35

Publicidad

loading

Este manual también es adecuado para:

Ts550-w28-u