3.2- Common Installation
The standard installation allows you to control the pump, chlorinator, and lights from the PC-
SMART+ using its different scheduling modes.
- The AC input is connected to single-phase power (230V AC).
- The Pump output is connected to the power supply of the single-phase pump.
- The Chlorinator output is connected to the power supply of the chlorinator (230V AC).
- The Aux output is a 230V output.
- The Temp input is connected to the temperature probe (NTC Kit).
Fig. 3: Example of common connections.
3.3- Installation with Remote Pump Activation
The Connectivity installation allows you to control the pump's scheduling through an external
contact to the PC-SMART+ panel via the Remote input.
Important: The Remote input is activated only through a dry contact; under no circumstances
apply voltage to the Remote input!
To enable remote mode, you must select it in the corresponding menu (Mode → Filtr. →
Remote). In this mode, the filtration pump will start when the contact on the Remote input is
closed and will stop when the contact is open.
27