4.6- Alarms
In the event of an alarm, the equipment will immediately shut down the pump and the
chlorinator. This will occur when the equipment detects a deviation in the pump's current
consumption.
You can adjust the sensitivity of the alarms, as well as their response time. For dry run and low
flow, you can also set automatic retries.
-
Overload: Performs the function of a traditional motor thermal circuit breaker.
(Current higher than the nominal)
-
Low Flow: Detects a clogged filter or partially closed valve.
(Current lower than the nominal)
-
Dry Run: Detects a completely closed valve or the pump operating without water (in a
dry state).
(Current below half of the nominal)
Fig. 15: Alarm selection.