OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the 'OFF'
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass® could pop up and
strike somebody's face during the process of lighting this unit; stand away from the unit for the first
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
Wait 50 minutes after extinguishing fame prior to placing a lid (if applicable) or protective cover on
heating item.
To Light
Be sure to remove the lid before lighting the fire pit.
To light the fire pit, push and turn the control knob (G) on the side of the body (B) counterclockwise to ignite the piezo
ignition. It may take several attempts to light the ignition.
To adjust the flame, turn the control knob (G) either clockwise or counterclockwise depending on whether you want to
lower or raise the flame.
To Extinguish
1. Push and turn the control knob (G) clockwise to turn off fire pit.
2. After fire pit is completely cool, lock lid in place by turning clockwise.
WARNING
Fire product and propane gas cylinder minimum
distance must be over 60 inches (as per right
side photo)
WARNING
If the burner does not ignite with the burner control
valve open, gas will continue to flow out of the burner
and could accidently ignite causing injury or property
damage.
Page 9