IX. SETTING UP SEVERAL CABINETS SIDE BY SIDE
Depending on the temperature and air humidity at the installation site as well as the selected
set point temperature, the moisture in the ambient air can condense on the surface of a
refrigerating unit due to its design.
If several cabinets are set up side by side, this condensation effect becomes stronger, and a
lower air quantity can circulate between the cabinets. As a result, a minimum distance of 30 to 50
mm must be kept between the cabinets depending on the temperature and air humidity.
These gaps must not be sealed either at the top or bottom, but can be covered by a stainless-
steel panel from the front for aesthetic purposes. The panel must be removable for cleaning within
the gaps.
If it is not possible for air to circulate freely at the bottom, e.g. due to a base installation, then the
gaps cannot be sealed at the front