SERVICE:
Reparaturen dürfen nur von qualifizierten Personen durchgeführt werden.
Es sind nur die vom Hersteller vorgeschriebenen Ersatzbauteile zu verwenden.
Technische Änderungen vorbehalten!
Operating instruction for electric fence controller ranger AS120 & ranger AS180
in connection with safety hints SECURA ANIMAL or
SECURA SECURITY(www.horizont.com/securaanimal or
www.horizont.com/securasecurity)
Energizer has to be turned OFF before any intervention!
ASSEMBLY AND CONNECTION:
Set the device up in as moist a location as possible. The supplied U earthing rod/set-up post
14498 or the optional 1m earthing rod (longitudinal rod) 14041-1 must be driven as deeply as
possible into the ground in a damp area and connected with a high voltage-resistant connecting
cable (e.g. 90150) with the black earth terminal (
high voltage-resistant fence cable (e.g. 90676U) to the red terminal with the lightning symbol (
). The device is only protected against moisture if it is properly assembled. Place the device on
the U earthing rod and do not operate it while it is lying on the ground. Set the device up in a non
fire-hazard location.
COMMISSIONING:
Switch the device on with the push-button switch (PG.36/
lights up in the same rhythm as the impulses. The device transmits impulses to the fence. If the
LED does not light, the 12 volt rechargeable battery is spent. It could also be a defect in the device
or at the 230 volt mains adapter.
The incorporated current saving circuit is self-regulating and consumes less energy with a well
insulated fence.
COMMISSIONING WITH 12 RECHERGABLE BATTERY
(PG. 33/FIG.3,4 & PG. 34/FIG.6):
Only use rechargeable 12 V lead batteries; rechargeable batteries with ventilation should
only be recharged in well-ventilated rooms. When charging with a charger that is not
listed in these instructions and is connected directly to the 12 V lead battery, you must
remove the rechargeable battery from the device. The rechargeable battery should be
stored and charged at normal room temperature before and after every use as well as
during longer periods of storage in the house (every 2 months).
Please check your battery regularly using the battery check indicator – especially in periods of
low sunlight - to avoid deep discharge of the battery. If necessary, charge the battery using the
enclosed mains adapter.
Attention: The energiser must be disconnected from the fence during the charging process!
The rechargeable battery must be recharged by the latest when it has discharged 80 % (only 20
% charge capacity left) to prevent complete discharge. The rechargeable battery indicator (PG.33