Maytag Commercial MDE17MN Instrucciones De Instalación página 12

Secadora eléctrica comerciale
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DRYER VENTING REQUIREMENTS
Vent Hoods
102 mm (4") Diameter Exhaust Hoods
box hood
louvered hood
Vent System Length
Maximum Vent Length/Vent Connection
Maximumlengthofventsystemdependsuponthetypeof
ventused,numberofelbows,andtypeofexhausthood.
Vent System Chart (Rigid Metal Vent)
No. of
90˚ Turns
Louvered Hood
0
19.5 m (64 ft.)
1
16.5 m (54 ft.)
2
13.4 m. (44 ft)
3
10.7 m (35 ft.)
4
8.2 m (27 ft.)
Forventsystemsnotcoveredbytheventspecificationchart,
seeyourpartsdistributor.
Provisionmustbemadeforenoughairforcombustionand
ventilation.(Checkgoverningcodesandordinances.)See
"RecessedAreaandClosetInstallationInstructions"inthe
"LocationRequirements"section.
A102mm(4")outlethoodispreferred.However,a64mm
(2
")outletexhausthoodmaybeused.A64mm(2
1
2
createsgreaterbackpressurethanotherhoodtypes.For
permanentinstallation,astationaryventsystemisrequired.
Connect Vent
1.  I fconnectingtoexistingvent,makesuretheventisclean.
2.  U singa102mm(4")clamp,connectventtoexhaustoutlet
in dryer.
NOTE: Do not remove vent collar.
12
angled hood
Box and
Angled
Hood
17.7 m (58 ft.)
14.6 m (48 ft.)
11.6 m (38 ft.)
8.8 m (29 ft.)
6.4 m (21 ft.)
1
Vent collar
Exhausthoodmustbeatleast305mm(12")fromtheground
oranyobjectthatmaybeinthepathoftheexhaust(suchas
flowers,rocks,bushes,orsnow).
3. TightenhoseclampwithPhillipsscrewdriver.
4. Makesuretheventissecuredtoexhausthoodwith
a102mm(4")clamp.
")outlet
2
5. Movedryerintofinalposition.Donotcrushorkinkvent.
Makesuredryerislevel.
305 mm min.
12" min.
(305 mm)
(12")

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mde17cs

Tabla de contenido