Engine Oil Filling - GENERGY NATURA Serie Instrucciones De Uso

Ocultar thumbs Ver también para NATURA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.4 Engine oil filling

NOTE: The machine is delivered without oil; do not attempt to start up the
machine without adding oil first!
Ensure that the generator is on a perfectly leveled surface to avoid mistakes in the
oil filling.
Remove the oil filling cap and pour oil in the hole until the maximum level shown in
the figure below is reached.
Oil capacity to the correct level according to the model is:
 Models 2000 to 3000W
 Models 4000 to 7000W
Use good quality SAE10W30 or SAE10W40 4-stroke motor oil. Recommended oil
classification: API "SJ" (USA) or ACEA "A3" (EUROPE) or more current (See
container specifications).
NOTE: Combustion using PROPANE is drier and at a higher temperature
compared to gasoline. To ensure the correct lubrication select high quality oil. Do
not use used oils, oils of unknown origins nor too cheap.
NOTE: Consider that the engine consumes some oil during usage. Check the
oil level before each use and refill if the level has diminished.
MAXIMUM LEVEL
MINIMUN LEVEL
0.6 liters.
1.1 liters.
59