4) Press the button SET to confirm . The display
briefly shows
. The receiver unit will
return to the normal mode .
5) Then set the identification number on the
transmitter
instruction manual of the
transmitter .
6.1.4 Lock function
When the lock function has been activated,
the REMOSET function will not be available
for the receiver unit (
chapter 6 .2) . From
the setting modes, you will only be able to
activate the mode for the lock function in order
to deactivate the lock .
Furthermore, it will not be possible to
switch off the complete IN-264R / 5 when at
least one of the two receiver units has been
locked .
Activating the lock
1) Keep the button SET (8) pressed until the
letter "G" starts flashing on the display; the
group setting mode is activated .
2) Press the button SET repeatedly until the
display shows
(lock off) and LOCK
(e) starts flashing .
3) To activate the lock, press the button
The display shows
.
4) Press the button SET to confirm . The display
briefly shows
. The receiver unit will
return to the normal mode .
The indication LOCK (e) on the display
shows that the lock has been activated .
When you press a button,
in addition .
Deactivating the lock
1) Keep the button SET (8) pressed until the
indication LOCK (e) starts flashing on the
display .
2) To deactivate the lock, press the button
(7) . The display shows
3) Press the button SET to confirm . The display
briefly shows
. The unit will return to
the normal mode .
6.2 Automatic frequency matching
(REMOSET function)
Via a 2 .4 GHz radio signal of the correspond-
ing receiver unit, the transmitter is matched
to the transmission frequency of this unit . The
range of REMOSET transmission may reach up
to 10 m . Transmission is not possible when the
receiver unit is locked (deactivating the lock
 chapter 6 .1 .4) .
After setting the desired transmission fre-
quency on the receiver unit (
and switching on the transmitter, press the but-
ton REMOSET (6) of the receiver unit . When
the REMOSET function has been activated, the
luminous ring of the button starts flashing rap-
idly . The display briefly shows the identification
number of the receiver unit (
After matching the frequency, the transmitter
is set to the channel group and the channel
of the receiver unit . The luminous ring of the
button lights permanently again .
If the luminous ring keeps flashing after the
REMOSET function has been activated, the
receiver unit does not receive a radio signal
from the transmitter on the transmission fre-
quency adjusted, e . g . when REMOSET trans-
mission has failed (troubleshooting
below) or when the transmitter is muted at
the time of REMOSET transmission .
If the transmitter has not been set to the channel
group and the channel of the receiver unit, check the
following adjustments on the transmitter:
 Has the lock function been activated on the trans-
mitter?
 Has the automatic frequency matching been dis-
abled on the transmitter?
 Does the identification number set on the trans-
mitter differ from the one set on the receiver unit?
Correct the corresponding setting on the transmitter
and press the button REMOSET once again .
(9) .

7.1 Transmission frequencies

Channel
1
appears
2
3
4
5
6
7
.
8
9
10
11
12
13
14
15
16
17
18
 chapter 6 .1 .1)
19
20
21
22
 chapter 6 .1 .3) .
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
box
A1
A2
A3
MHz
MHz
MHz
507 .275
506 .250
506 .500
508 .100
506 .750
507 .150
510 .625
508 .750
508 .500
512 .275
510 .000
509 .200
512 .875
511 .000
510 .650
520 .575
511 .500
511 .400
525 .050
512 .375
513 .100
530 .950
513 .375
514 .500
534 .900
513 .875
517 .100
535 .825
514 .625
518 .900
537 .425
517 .250
520 .050
538 .050
518 .375
521 .950
539 .550
520 .125
526 .150
509 .225
521 .625
528 .800
526 .400
523 .250
529 .600
518 .850
524 .250
535 .100
521 .400
525 .875
536 .350
522 .925
529 .000
539 .750
524 .100
531 .125
525 .625
534 .875
532 .775
540 .375
541 .875
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
®
7 Specifications
Carrier frequency range: � � 506 – 542 MHz
table below
REMOSET transmission: � � 2�4 GHz
Audio frequency range: � � 40 – 18 000 Hz
THD: � � � � � � � � � � � � � � � � < 0�6 %
Dynamic range: � � � � � � � � > 105 dB
Squelch: � � � � � � � � � � � � � pilot tone / noise mute
Audio outputs
AF OUTPUT RX 1 / RX 2: � 100 mV, XLR, bal�
AF OUTPUT Mixed: � � � � 100 mV,
6�3 mm jack, bal�
Switchable attenuation
for each audio output: � � � 10 dB, 20 dB
Ambient temperature: � � � 0 – 40 °C
Power supply: � � � � � � � � � via power supply unit
provided and con-
nected to 230 V/ 50 Hz
Dimensions W × H × D
(w /o antennas): � � � � � � � � 420 × 54 × 230 mm
Weight: � � � � � � � � � � � � � � 2 kg
Group
A4
A5
MHz
MHz
506 .750
507 .100
507 .250
508 .700
509 .250
509 .400
510 .500
510 .900
511 .500
511 .925
512 .000
512 .675
512 .875
514 .100
513 .875
515 .675
514 .375
516 .500
515 .125
517 .825
517 .750
521 .300
518 .875
523 .450
520 .625
525 .300
522 .125
526 .475
523 .750
528 .700
524 .750
531 .825
526 .375
532 .625
529 .500
533 .725
531 .625
534 .600
535 .375
535 .750
540 .875
536 .300
Subject to technical modification .
A6
MHz
507 .850
509 .450
510 .150
511 .650
512 .675
513 .425
514 .850
516 .425
517 .250
518 .575
522 .050
524 .200
526 .050
527 .225
529 .450
532 .575
533 .375
534 .475
535 .350
536 .500
537 .050