10.2 CONDITIONS OF USE

Non-compliance with the unit
 This manual:
MUST be read carefully and understood before carrying out any operations on the unit;
MUST be strictly complied with;
MUST always be at hand in the place where the unit is used.
 Installation must only be carried out by qualified personnel.
The maximum pressure differentials given in the "SPECIFICATIONS
as a blower:
intake temperature 20°C (+68°F) and atmospheric pressure 1013 mbar (abs.) (29.92 In Hg ) measured at the inlet port
as an exhauster:
intake temperature 20°C (+68°F) measured at the inlet port and atmospheric backpressure 1013 mbar (abs.) (29.92 In Hg).
The ambient temperature, like the conveyed gas intake temperature, is
permissible inside the range -15°C (+5°F) ÷ +40°C (+104°F) with the
following provisions;
for ambient temperature +30°C (+86°F) reduce the maximum
pressure differentials given in the "SPECIFICATIONS
5%;
for ambient temperature +40°C (+104°F) reduce the
maximum
pressure
"SPECIFICATIONS
The graph to be used to reduce the maximum pressure differentials in
case of ambient temperature between +21°C and +40°C (or between
+70°F and +104°F) is given opposite
The maximum height at which the unit can be installed is 1000m a.s.l.; if higher, contact the FPZ S.p.A. After-Sales Service.
In case of suction in the place or on the system, protect the intake pipe with an ATEX filter with recommended maximum filtration 20
µm / 25µm. For the use of filters with different degree of filtration, contact the FPZ S.p.A. After-Sales Service. Check compliance with
the maximum pressure / vacuum data given in the "SPECIFICATIONS".
To ensure machine operation within the maximum pressure differentials indicated in the "SPECIFICATIONS",
ATTENTION!
it is advisable to use a device for limiting the vacuum / pressure rather than throttling the suction or delivery.
ATTENTION!
If installed outdoors, protect the unit against the sun and weather.

10.3 GENERIC MATERIAL LIST

Given below is a list of the materials in the units in contact with air / gas
PARTS
body
cover
impeller
manifold
silencer housing
soundproofing material
soundproofing material support screen
sealing ring
impeller locking washer
motor shaft / transmission
Housing adapter
FPZ-MI-R-MD-MOR-GOR-ATEX-15-R00
'
s intended use can cause serious accidents.
differentials
given
"
by 10%.
RXX MD MOR/GOR - ATEX 3GD
Aluminium AC-45000SF
Aluminium AC-45000SF
Aluminium AC-45000SF
Aluminium AC-46100SF
Self-extinguishing polyurethane
Aluminium AC-46100SF
"
refer to the following operating conditions:
12
11
10
9
"
8
by
7
6
5
4
in
the
3
2
1
0
20
22
Not foreseen
Steel AISI 304
Guaflon VGX
Steel AISI 303
Steel C40 / C45
36 / 111
24
26
28
30
32
34
36
38
Ambient temperature °C
RXX MD GOR - ATEX 2G
Aluminium AC-45000SF
Aluminium AC-45000SF
Aluminium AC-45000SF
Aluminium AC-45000SF
Not foreseen
Not foreseen
Not foreseen
Guaflon EXD
Steel AISI 303
Steel C40 / C45
Not foreseen
40
42
44