Commissioning
Code
No.
Name
Analog input dead
C31
band
Configuration -
C34
analog input
Voltage - DC
C36
injection brake
(DCB)
Fixed setpoint 1
C37
(JOG 1)
Fixed setpoint 2
C38
(JOG 2)
Fixed setpoint 3
C39
(JOG 3)
Frequency setpoint
C46
Output frequency
C50
DC bus voltage
C53
Motor current
C54
PI feedback
C59
Proportional gain
C70
Integral gain
C71
Input voltage
C90
selection
User password
C94
Software version
C99
Acceleration time 2
c01
Deceleration time 2
c03
16
Possible Settings
Selection
Lenze
0
0
Enabled
1
Disabled
0
0
0...10 V
1
0...5 V
2
0...20 mA
3
4...20 mA
4
4...20 mA monitored
4.0
0.0
{%}
20.0 0.0
{Hz}
30.0 0.0
{Hz}
40.0 0.0
{Hz}
0.0
{Hz}
0.0
{Hz}
0.0
{%}
0.0
{%}
c86
{%}
5.0
0.0
{%}
0.0
0.0
{s}
0
Auto
1
Low
2
High
Note
• To simplify commissioning, the Lenze setting is preset at the factory, depending
on model:
C90 = 1 for 400/480 V models
C90 = 2 for 230/240 V models
• Upon reset (C02 = 1, 2), C90 = 0. Confirm correct setting after next power-up.
0
0
Changing from "0" (no password),
value will start at 763
5.0
0.0
{s}
5.0
0.0
{s}
C31 = 0 activates dead band for analog
input. When analog signal is within dead
band, controller's output = 0.0 Hz and
display will read
Will trigger
2 mA
50.0
• See CE1...CE3 and c06
• Confirm motor suitability for use with
DC braking
999
When PI is active (see d38), C37...C39
are fixed PI setpoints
999
999
500
Display: Setpoint via analog input,
function UP/DOWN, or LECOM
500
Display
255
Display
255
Display
c87
Display
99.9
99.9
Automatically sets to Low (1) or High
(2) upon next power-up, depending on
input voltage
For 200 V or 400 V input
For 240 V or 480 V input
999
When set to a value other than 0,
must enter password at C00 to access
parameters
Display, format: x.yz
999
• Activated using CE1...CE3
• c01 = frequency change 0 Hz...C11
999
• c03 = frequency change C11...0 Hz
• For S-ramp accel/decel, adjust c82
Lenze 13466184 EDBSL03 v20 EN, DE, FR, IT, ES
IMPORTANT
StP
SD5
fault if signal falls below

Publicidad