N.B.: IMPORTANT FOR INSTALLATION CONDITIONS
fi g. 9
External
intake
METAL FINISHING PROFILE (supplied)
If necessary, after opening the external door, it is possible to
mount the "angled" metal fi nishing profi le on the lower base of
the structure (X - for "frame" coverings or with plasterboard)
or the "fl at" metal fi nishing profi le (Y- for "classic" coverings),
fi xing them using the screws supplied (see fi g. 10).
NOTES ON FITTING THE COVERING
In using a prefabricated Edilkamin covering, to identify the
exact position of INPELLET 49 is important to verify the mo-
del of the covering to be used.
Positioning differs according to the model chosen (see as-
sembly instructions given in the packaging of each covering).
Always check that installation is perfectly vertical and horizon-
tal.
COVERINGS, COUNTER-HOODS AND THEIR
VENTILATION
Before installing the covering, check that all connections, com-
mands and moving parts are perfectly functional.
Check this with the insert on and working for a few hours. Do
so prior to fi tting the covering in order to intervene as necessa-
ry.
Finishing works, such as construction of the counter-hood,
covering assembly, pilaster preparation, painting, etc.,
should be carried out once the fi nal test has been passed.
Edilkamin will therefore not be held liable for any charges
deriving from both demolition and reconstruction works,
even where consequent to replacement of any faulty insert
parts.
INSTALLATION
*
Internal mantel
ventilation grilled
*
Recycled air
intake inspection
- 31
*
There must be two ventilation grilles (surfaces greater than
300 cm²); the fi rst must be at a height which is lower than the
hearth, while the second must at a height greater than 30cm
with respect to the upper profi le of the outlet.
These grilles prevent the accumulation of heat inside, which is
then used to help heat the room of installation.
X
fi g. 10
Rather, at least 1 cm. (approx.) space must be left to allow
air to fl ow, thereby preventing heat from accumulating.
The counter-hood can be created from fi reproof plaster-
board panels or plaster sheets. When creating this, the air
circulation grill must be included, as previously specifi ed.
- THE MANTEL CAN BE CONSTRUCTED WITH FIRE
RESISTANT PANELS IN PLASTERBOARD OR
GYPSUM BOARD.
- AERATION GRILLES FOR PREVENTING ANY
EXCESS TEMPERATURE INSIDE MUST BE PROVI-
DED FOR DURING CONSTRUCTION (fi g. 9).
During the construction phase of the covering it is funda-
mental to ensure that the combustion air is restored
to prevent pressure phenomena in the room where the
fi replace is installed (refer to the Chapter regarding the
external air inlet on page 27)
In addition to the above, always consider the indications gi-
ven by paragraphs 4.4 and 4.7 of standard UNI 10683/2005
"insulation, fi nishes, coverings and safety recommenda-
tions".
-
Y