INSTRUCTIONS FOR USE
1st ignition/test by the Edilkamin authorised Dealer
Start-up must be carried out as prescribed by point 3.21 of standard UNI 10683.
This standard indicates the control operations to be carried out in situ, aimed at ascertaining correct system function.
Before igniting.
1st ignition: contact your local Dealer, who will calibrate the insert based on and in compliance with installation conditions.
Failure to have an authorised Edilkamin DEALER perform start-up will void the guarantee.
They will calibrate the insert according to the type of pellets available and the conditions of use.
There may be a slight smell of paint the fi rst few times it is ignited. This will disappear quickly.
Before igniting, check:
• that installation is correct
• electricity supply
• that the door closes correctly
• that the combustion chamber is clean
• stand-by indicated on the remote control display: hours (fi xed display), ambient temperature and the reserve (or kg of pellets in
the tank) will fl ash alternately on the display.
Filling the cochlea.
The fi rst time you use the product, or should the tank be completely emptied of pellets, to fi ll the coclea press both keys "+"
and "–" on the remote control at the same time, holding for a few seconds. As you release the keys, the display should show the
wording "LOAD". This should be carried out before ignition if the insert has stopped due to having run out of pellets, at the end of
operation to empty the combustion pot before turning.
It is quite normal for some pellets to remain, that the cochlea cannot suction.
Automatic igniting.
With the insert on stand-by, press and hold the key
, on the remote control for 2 seconds. This will start-up the
ignition procedure, showing the wording "START". At the same time, a countdown in seconds begins (from 1020 to 0).
Ignition is not at a preset time, however: its duration is automatically shortened if the board reports that certain tests have
been passed. The fl ame appears after about 5 minutes.
Manual igniting.
Temperatures of below 3°C will not allow the electrical resistance to heat suffi ciently. In this case, or should the
resistance be temporarily out of action, Diavolina® type fi re-starters can be used.
Insert a piece of lit Diavolina into the combustion chamber, close the door and press
the remote control.
POWER REGULATION
• Remote control manual operation
With the insert working, press the key "M" on the remote control once. The display will show the word "POWER P".
(specifying the power at which the insert is working). Press the keys "+" or "–" to increase or decrease the insert's
working power (from "POWER P1" to "POWER P5").
• Remote control automatic operation
Press key "A" to switch to automatic operation, adjusting the temperature desired for the room (use the "+" and "–" keys
to set the temperature from 5°C to 35°C, and the insert will regulate working power required to reach the temperature set.
If a temperature below that of the room is set, the insert will stay on "POWER P1".
Turning off
With the insert running, press and hold the key
rom the remote control for 2 seconds. The turn-off procedure will begin,
showing a countdown on the display from 9 to 0 (for a total of 10 minutes).
The turn-off phase involves:
• Interruption of pellet supply
• Maximum ventilation.
• Smoke expulsion motor.
Never pull the plug out whilst the device is still in the process of turning off.
OPERATIONS THAT CAN ONLY BE CARRIED OUT BY REMOTE CONTROL
Clock regulation
Press and hold the key "M" for 2 seconds to access the "Clock" menu. This allows you to set the internal electronic board
clock. By then pressing the key "M", the following data appears in sequence and can be regulated:
day, month, year, hour, minutes, day of the week.