Warranty Conditions; Rules For Returning And Rapairing; Risk Of Electromagnetic Interference And Possible Remedies - Ca-Mi AS-200 Manual De Instrucciones

Aspirador
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
This product is guaranteed for a period of 24 months from the date of purchase. The warranty includes the repair or replacement
of defect spare parts free of charge, if the defect has been clearly described by the customer and determined by technical service.
Inspections on the part of the seller, performed at the request of the customer and intended to determined wjether the device is
fully functional, are not covered by the free-of-charge warranty service. This service will be charged to the customer depending on
the effort required. The consumables components are not subject to warranty. Consumable components are silicon tubes, filters,
seals, conical adaptor and suction catheter. Also exluded from warranty is all damage resulting from improper handling, wilful
damage or improper care of the device.
The warranty shall expire if repairs and servicing are not carried out by technical service.
UNDER NEW EUROPEAN RULES, CA-MI REQUIRES THE FOLLOWING PROCEDURES TO BE CARRIED OUT TO PROTECT THE
INSTRUMENT AND THE SAFETY OF ALL WHO COME IN CONTACT WITH IT.
CA-MI warrants it's product for 24 months after purchasing date.
Before returning an instrument for repair, the external surfaces and all accessories MUST be carefully disinfected with a cloth
soaked in methylated spirits or hypochlorite-based solution. The instrument and accessories should then be placed in a bag with a
note outlining the disinfection undertaken.
Failure to follow this procedure will result in the instrument being returned to the purchaser unrepaired.
Instruments returned for repair MUST be accompanied by a description of the problem. CA-MI will not be responsible for damage
caused through improper use. To avoid such damage, please read the instruction carefully.
Where CA-MI determines that an instrument is faulty, a replacement will be provided only if a SALES RECEIPT and STAMPED
GUARANTEE are provided. CA-MI will not be responsible for damage accessories. These may be replaced at the customer's
expence.

RISK OF ELECTROMAGNETIC INTERFERENCE AND POSSIBLE REMEDIES

This section contains information regarding the conformity of the compliance with the EN 60601-1-2 Standard.
The AS-200 surgical aspirator is an electro-medical device that requires particular precautions regarding electro-magnetic
compatibility and which must be installed and commissioned according to the electro-magnetic compatibility information
supplied. Portable and mobile radio communication devices (mobile phones, transceivers, etc.) may interfere with the medical
device and should not be used in close proximity with, adjacent to or on top of the medical device. If such use is necessary and
unavoidable, special precautions should be taken so that the electro-medical device functions properly in its intended operating
configuration (for example, constantly and visually checking for the absence of anomalies or malfunctions).
The use of accessories, transducers and cables different to those specified, with the exception of transducers and cables sold by
the appliance and system manufacturer as spare parts, can lead to an increase in emissions or in a decrease of the immunity of
the device or system. The following tables supply information regarding the EMC (Electromagnetic Compatibility)
characteristics of the electro-medical device.
The surgical aspirator AS-200 is intended for use in the electromagnetic environment specified below.
The customers or the user of the surgical aspirator AS-200 should assure that it's used in such an environment.
Emissions test
Irradiated / Conducted emissions
CISPR11
Irradiated / Conducted emissions CISPR11
Harmonic emissions EN 61000-3-2
Voltage fluctuations / flicker emissions
EN 61000-3-3

WARRANTY CONDITIONS

RULES FOR RETURNING AND RAPAIRING

Guidance and manufacturer's declaration – electromagnetic Emissions
Compliance
Group 1
Class [B]
Class [A]
Complies
Electromagnetic environment - guidance
The surgical aspirator AS-200 only used RF energy only for
its internal functioning. Therefore, its RF emissions are very
low and are not cause interference in proximity of any
Electronic appliances.
The surgical aspirator AS-200 can be used in all
environments, including domestic and those connected
directly to the public mains distribution that supplies power
to environments used for domestic scopes.