6
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
To J24 on I-O PCB
(Sht 2, D3)
RIBBON CABLE 30 ckt.
CCM (J31-33) - INVERTER (J100)
(Sht 2, C4)
1 Ready
2 Ready_RTN
3 INVERTER_FLT
4 INVERTER_FLT_RTN
5 OVERTEMP_FLT
6 OVERTEMP_FLT_RTN
7 SPARE
8 SPARE_RTN
9 VAC_SELA
10 1VAC_SELB
11 1OUT_COM (+5V)
12 IS_IDA
13 IS_IDB
14 IS_IDC
15 ENABLE
16 ENABLE_RTN
17 START2
18 START2_RTN
19 215 OHM TO COMM
20 SYNC
21 SYNC/
22 215 OHM TO COMM
23 NC
24 COMM
25 DEMAND +
26 DEMAND-
27 COMM
28 CURRENT+
29 CURRENT-
30 COMM
Rev
Rev
Revision
Revision
00
Initial Design
0
1
Added MC3 Pump Control
0
2
Added R1, K1, MC1 inrush
6
Manual n.º 0-5284ES
7
TO CCM
CPU PCB J33
(Sht 2, C3)
J102A
(49C)
5
4
(51C)
3
2
PILOT BOARD
1
LED'S
D2 PILOT ENABLE
D11 +5V
TO CCM
CPU PCB
TEST POINTS
J32
TP1 GND
TP2 PILOT GATE
(Sht 2, B3)
TP3 +5V
J102B
(49B)
5
4
(49)
3
(51B)
2
1
J43
TO CCM
CPU PCB
J31
(Sht 2, B3)
J102A
(49A)
INVERTER
5
4
J40
3
(50)
2
5
1
4
3
2
1
019X501600
019X501600
TO RELAY BOARD
(51A)
J42
TO J3 on RELAY PCB
10 ckt Ribbon
(Sht 2, A6)
(53)
TIP VOLTS
(51)
WORK
(55)
ARC VOLTS
(51A)
(Sht 1, A6, B6)
(51)
(56)
(57)
TO J1 on RELAY PCB
(58)
(Sht 2, A5)
(59)
RIBBON CABLE 40 ckt CCM (J23 (Sht 2, C7)) - RELAY PCB (J4 (Sht 2, B7))
1
COMMON
2 /1TORCH START *
3
NA
4 /1TORCH GAS SOL ON *
5 /MAIN TORCH IDLE *
6 /1TORCH PRESS OK *
7
FLOW SENSOR (pulses)
8
LOW COOLANT FLOW
9
COOLANT LEVEL OK
10 COMMON
11 NA
12 /PLASMA ENABLE-HMI
13 /COOLANT PUMP ON
14 COMMON
15 /PILOT ENABLE
16 /RAS ON
17 /CONTACTORS ON
18 COMMON
19 /COOLANT FANS ON
20 /1TORCH CONTACTOR ON *
* Used with 1 Torch Option
By
By
Date
Date
Rev
Rev
Revision
Revision
DAT
4/18/2012
D
A
T
8
3 /
1
2 /
0
1
2
D
A
T
1
1 /
6
2 /
0
1
3
7
8
9
T2
SG1
6.5K 1W
(99)
AC 120V (Sht 2, A8)
0.062"
(98)
AC 120V_RET (Sht 2, A8)
6.5K 1W
120 / 6000 VAC
(49)
Toriod Core
NEG
CGND
PLT
(52)
CHASSIS GND
ELECTRODE
PILOT PCB
J44
1
J41
(52)
2
1
TIP
TO I/O BOARD
J45
TB4
(49)
ARC VOLTS (TORCH)
7
6
(51)
WORK
5
(60)
AC 120V- TB4-4 (Sht 2, B8)
4
(61)
120 VAC @ 100 ma.
AC 120V- Ret- TB4-3 (Sht 2, B8)
3
(62)
AC 24V-TB4-2 (Sht 2, B8)
2
(63)
24 VAC @ 1A
AC 24V- Ret -TB4-1 (Sht 2, B8)
1
Hall Effect Sensor
HCT1
J16
+15 VDC
-15 VDC
SIG (+)
COMMON
21 /PLASMA ENABLE RELAY
22 COMMON
RIBBON CABLE 16 ckt
23 PILOT CURRENT SIG-
CCM ( J37 (Sht 2, C8)) -
24 NC
DISPLAY PCB (J17 (Sht 2, C9))
25 PILOT CURRENT SIG+
1,3,5,7
24 VDC
26 COMMON
2,4,6,8
COMMON
27 WORK CURRENT SIG-
9,10
NC
28 WORK CURRENT SIG+
11-16
SERIAL DATA
29 NC
30 AMBIENT TEMP
RIBBON CABLE 10 ckt
31 COOLANT TEMP
RELAY PCB (J3 (Sht 2, A6)) -
32 COMMON
PILOT PCB (J42 (Sht 1, C8))
33 -15 VDC
34 COMMON
1,2
24 VAC
35 24 VDC
3,4,7,10
COMMON
36 COMMON
5
PILOT ENABLE +
37 24 VDC
6
PILOT ENABLE –
38 COMMON
8
PILOT CURRENT SIG –
39 24 VDC
9
PILOT CURRENT SIG +
40 COMMON
By
By
Date
Date
The information contained herein is proprietary to Victor Technologies.
Not for release, reproduction or distribution without written consent.
Title
Title
SCHEMATIC
Auto-Cut XT 200A CE 380-415 VAC
8
9
A-33
Auto-cut 200 Xt
10
C1
C2
(49)
A
C3
L2
(49)
L3
HF COIL_WC
B
TORCH
PILOT
1
SHIELD
CHASSIS GND
(-)
C
(+)
Tip
WORK
(+)
Work
1
D
E
Art # A-11944
Victor Technologies Headquarters
16052 Swingley Ridge Road, Suite 300
St Louis, Missouri 63017 USA
F
Date Printed
Date Printed
Date Revised
Date Revised
4/8/2013
3/8/2013
Drawn
Drawn
Date
Date
04/18/2012
DAT
Size
Size
Sheet
Sheet
C
1
2
of
Drawing Number
Drawing Number
042X1350
10
APÉNDICE