How To Use The Dryer Using A Standard Programme; How To Use The Dryer Using Settings Defined By The Operator; Alarms And Warnings - Domus DTA-11 Manual De Usuario

Ocultar thumbs Ver también para DTA-11:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.6.

How to use the dryer using a standard programme

When the machine is on STAND-BY, push the arrows to select the desired programme.
Once the display show the desired program push the start button and it begins immediately.
4.7.

How to use the dryer using settings defined by the operator

When the machine is on STAND BY, press the SELECT key when you will see 65º (Drying
temperature) flashing and with the keys INCREASE or DECREASE the temperature may be
modified. Push SELECT again to see 60' (Drying Time) and change it with the keys INCREASE or
DECREASE.
Press START/STOP to begin the cycle.
Note: The last pre-selection made is the one which, by default, is used in the following drying
programme.
Those values could be modified also with the machine running.

5. ALARMS AND WARNINGS

The open door or open filter alarms pause the programme in course and sound a warning, when the
alarm conditions disappear the drying programme may continue once the alarm has been switched
off.
The other alarms stop the programme and sound a warning. This warning sound can be stopped by
pressing any key or eliminating the problem that caused the alarm.
In the following table there is a list of all the alarms and their possible solutions.
Alarm
Meaning
AL-1
Door open
AL-2
Filter cover open
AL-3
No flame
AL-4
Insufficient Air flow
AL-5
Fan-motor overload
AL-6
Over heating
AL-7
Filter dirt
AL-8
Transmission
AL-9
Probe alarm
If any of the alarms continue, consult the After Sales Service. Always quote the machine serial
number in your enquiries.
DTA-DTP-11-18-27_Manual_ML
Possible solutions
* Close the door.
* Close the cover
* Check gas supply tap is open.
* Check pressure is correct. See 3.4.
* Ensure the blow off pipe is not blocked; check that it is not
excessively long. See 3.3.
* Check the filter is clean.
* Check the fan wheel is clean.
* Ensure the blow off pipe is connected correctly, that it is not
blocked.
* Check the Intensity on the motor.
* Check air flow.
* Check gas pressure
* Clean the filter.
* Clean the filter on a regular basis. Do not wait for the alarm
* Contact After Sales Service.
* Contact After Sales Service. Check humidity sensor.
Página 52 de 109

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dtp-11Dta-18Dtp-18Dta-27Dtp-27

Tabla de contenido