INSTALLATION
Mechanical stop in opening adjustment
Mechanical stop in closing adjustment
54
Installation manual
1 Programme the control panel in "dead man mode":
F103.
2 Use ST1 and ST2 to open the gate up to the required
point.
See the control board instructions for
detailed information.
3 Adjust the screw-stopper (1) until it comes into
contact with the metal base box (2).
4 Lock the screw (1) by fastening the counter nut (3).
The gate must have an external in-ground
central stop (see "Fig. 1 Elements of the
complete installation" on page 43).
1 Use ST1 and ST2 to close the gate up to the required
point.
See the control board instructions for
detailed information.
2 Adjust the screw-stopper (1) until it comes into
contact with the motor arm (2).
3 Lock the screw (1) by fastening the counter nut (3).