OPERATION
FIGURE 21
Note: Avoid using food products
that produce fl ames near downdraft.
Controls (Fig.21)
Button "—" : Pressing this button for more than 2
seconds turns the blower off.
Pressing the button quickly while the blower is on
will decrease the blower speed.
Button "+": Pressing this button for more than 2
seconds turns the blower on.
Pressing the button quickly while the blower is on
will decrease the blower speed.
LED 1, 2 and 3 display the speeds.
Function Timer 10 Minute
After pressing the button "+" for more than 2
seconds, the 10 minute timer will be activated.
The LED of the current speed begins to blink, to
show this function. After 10 minutes the blower
will be turned off. Changing the speed while the
Timer is on, will NOT deactivate this function. To
deactivate this function, press button "+"for more
than 2 seconds.
Filter alarm
Filter ALARM 30H: after 30 hours of operation, the
alarm for cleaning the grease fi lter, will turn on.
Once activated, the fi lter alarm will be displayed
for 30 seconds each time the downdraft is turned
off. This alarm is displayed by the #2 LED and will
blink or remain on.
To reset the alarm, press and hold the "-" button
for 2 seconds. The #2 LED will blink twuice, ve-
rifyng the downdraft has been reset.
Auto-Off Timer
After 10 hours on continuous blower operation
without user interaction, the downdraft will auto-
matically turn the blower off.
- 13 -