MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S
LINE INPUT FUSE
"PEDESTRIAN ENTRY" FUNCTION
BUILT-IN FLASHING LIGHT CIRCUIT
"MAN PRESENT" FUNCTION
ELECTRIC BRAKING
WEEKLY TIMER INPUT
ENCODER SENSOR FOR OBSTACLE DETECTION
RECEIVER CONNECTOR
This product must be correctly installed by a qualified fitter. The maker declines all liability for
damage caused by incapacity or neglect.
In particular:
1. position the board vertically and as near as possible to the gear motor, taking care to keep
the connection cables as short as possible;
2. make sure the cross-section of the power cables (power input, motors, earth and flashing
light) is at least 1.5 mm² and, in any case, sufficient for the absorption and length of the
wires. The above also applies to the other cables used by control and auxiliary devices ex-
cept that the minimum cross-section is reduced to 0.5 mm²;
3. make connections to the terminal board so as not to alter the level of protection offered by
the container which must be installed in a dry and protected place;
4. keep the power circuits separate from the control and auxiliary circuits, especially if the
cables are long;
5. short any unused Normally Closed contacts.
NB:
the product must be properly earthed and the safety regulations in force in the
country of installation must be observed.
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to
avoid breakdowns of the line and false contacts.
-
do not re-use old pre-existing cables.
When all connections have been made:
 All the green LS LED's must be on (each corresponds to a Normally Closed input).
 They only turn off when the commands they are associated with are active.
 All the red LS LED's must be off (each corresponds to a Normally Open input) they only turn
on when the commands they are associated with are active.
Power input to board
Nominal power
Primary input line rapid fuse (F2 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
24Vac line rapid fuse (F1 - 5x20)
Logic circuit input voltage
Working temperature
Box protected to
12
CONTROL PANEL FOR 230 Vac SINGLE-PHASE MOTOR
D704M

TECHNICAL CHARACTERISTICS

230 Vac - 50÷60Hz
F1,6A - 250Vac
F1,6A - 250Vac
-20°C ÷ + 70 °C
English
INSTALLATION
TESTING
600 W ca.
230 Vac
24 Vac
5 Vdc
IP43