6. 3-Wire Conduit Installation
Remove the 3 screws from the connector block Insert
bare wires between the connector block terminals and
movable nuts, Tighten screws securely, Do not remove
ground strap connection
WARNING: Connector
block is approved
for copper
wire connection only. if aluminum
wire is used, see
note below,
NOTE: ALUMINUM WIRING
be
Do not connect aluminum
wire to connector block.
Use copper building wire rated for the correct
amperage and voltage to make 3 (three) 3" copper
jumper wires, Connect wire as per Step 6 or 7
depending on number of wires°
Splice copper wires to aluminum wiring using special
connector terminals designed and UL-approved for
joining copper to aluminum and fotlow the connector
manufacturer's
recommended
procedure closely,
Wire used, location and enclosure of splices,
etc., must conform to good wiring practices
and local codes.
€_:p,._
i_
Screw
b,oo.
Bare wire -_
Movable nut--.-]t_
"_P_
Flex|b_e cable
7. 4-Wire Conduit
Installation
Remove the 3 screws from the connector block, Remove
the grounding strap from the connector block middle
location and the screw connecting it to the frame of the
range, Insert bare wires between the connector block
terminals and movable nuts Tighten screws securely,
Attach ground wire to the frame of the range,
WARNING: Connector block is approved for copper
wire connection only. If aluminum wire is used, see
note below.
NOTE: ALUMINUM WIRING
a.
b.
Do not connect aluminum wire to connector block.
Use copper building wire rated for the correct
amperage and voltage to make 3 (three) 3" copper
jumper wires, Connect wire as per Step 6 or 7
depending on number of wires,
Splice copper wires to aluminum wiring using special
connector terminals designed and UL-approved for
joining copper to aluminum and follow the connector
manufacturer's recommended
procedure closely,
Wire used, location
and enclosure of splices,
etc., must conform to good wiring practices
and local codes.
_--_
Screw
j_l
terminal
_--_,.r-===
Co _'m e ct or block
Bare wire
.._ €_:-_,....._..._
Movab,e nut _"_
_)
I
Flexible
cable
Bracket
Conduit
ips
Connector
bleek---_
Bracket
!
_t.__re
wire tips
"_Q -,K------
Grounding
plate
_._P-_
Conduit
18