MOUNTING THE CONTROLLER

1. Open the cabinet door and TM mounting plate. Position the
controller on the wall and mark the top mounting hole location.
2. Install the top mounting screw leaving the screw head about
1/8" (3 mm) out from the wall.
Note: Use the correct type of screws for the wall construction
material. For masonry or dry wall, install screw anchors to enable
screws to be tightened securely.
4. Hang the controller on the screw. Install the lower mounting screw
and tighten both screws to ensure the controller is securely fastened.
INSTALLING CONDUIT
Note: Electrical conduit and adapters are not supplied with the
controller but may be required for installation in your area. Check local
electrical codes and install conduit according to requirements.
1. For power wires, remove the terminal strip cover located below the
transformer. Install a conduit from the circuit breaker panel to the
controller cabinet using the 1/2" (13 mm) thru-hole or 3/4" (19 mm)
conduit knockout.
2. For field wiring, either 2" (51 mm) or 3" (75 mm) conduit can be
installed. If 3" (75 mm) is required, remove the knockout ring
provided to increase the hole size. Sufficient space is provided to
enable either a hex nut or star nut to be installed on the conduit
fitting.

CONNECTING THE POWER WIRES

WARNING: All electrical components must meet applicable national
and local electrical codes including installation by qualified personnel.
These codes may require a means in the fixed wiring of disconnecting
AC power having a contact separation of at least 0.120" (1/8" or 3mm) in
the line and neutral poles. Ensure the AC power source is OFF prior to
connecting to the controller. The wire used for connection to the
controller must have insulation rated at 105°C minimum.
Caution: Do not connect the controller to one phase of a three-phase
power supply used by a pump or other electrical equipment.
1. Ensure the power is disconnected at the source. See Warning above.
2. Route the AC power and equipment ground wires through electrical
conduit to the controller.