CONTROLLER COMPONENTS

F
IGURE
1
LCD Display: For viewing time, program and status information.
2
+ /On & – /Off Buttons: For entry of program information.
3
Next Button: For selection of information to be programmed or reviewed.
4
Function Dial: For selecting the programming and operating functions.
5
Current Time & Date: For setting the current time and date.
6
Latch Knobs: Quick-release latches for hinged TM control panel.
7
Station Times: For setting individual watering time for each station.
8
Program Select Switch: For selection of programs A, B, C or D.
9
Program Start Times: For setting the time each program cycle will start.
10
Watering Days: For setting a watering day schedule for each program.
11
% Season Adjust/Program Stacking(dual function): For the increase or
decrease of station times for all stations within a program without changing
program memory (% Season Adjust). To the set number of programs (1–4)
which can operate simultaneously. Remote Radio Communication is also
enabled or disabled in this function.
12
Sensor Control Switch: To override rain switch sensor input.
13
Program Erase: For erasing information within a selected program.
14
Manual Program Cycle: For manual operation start of a selected program
watering cycle.
15
Manual Single Station: For timed or untimed operation of a single
station.
16
Off / Rain Delay: For immediate shut down of all controller output.
Programmable output delay for 1–7 days (Rain Delay).
17
Run: For automatic operation.
F
IGURE
18
Remote Port: Connection port for optional remote control receiver.
19
Spare Fuse Holder: Holds a 2.0A slow-blow spare fuse.
20
Valve Common Terminals: For the connection of up to four field (24V)
common wires.
21
Valve Wire Terminals: For the connection of valve control wires.
22
Earth Ground Lugs: For connection of a 6 AWG (10 mm
ground wire(s).
23
Terminal Strip: For the connection of 120 or 230–240 V a.c. power wiring.
24
Master Valve Terminal: For the connection of a master valve or pump
start relay control wire.
25
Sensor Connection Terminals: For the connection an optional normally-
closed Toro rain switch device.
26
Hot Post: 24 V a.c. output for valve zone identification.
27
Battery Compartment: 9-volt alkaline battery access compartment.
28
Safety Fuse: Replaceable 2.0A slow-blow fuse provides protection from
2
an internal short-circuit condition.
1
2
) copper
2