TFA_No_35.1077_Anleitung_01/11
Alarm signal
When a set weather alarm condition has been triggered, that particular alarm
will sound for 120 seconds. The corresponding value, "HI AL" or "LO AL" and
the alarm symbol are flashing until the weather condition doesn't meet the user
set level. Press any key to mute the alarm.
Example
Dew point high alarm was triggered:
digit flashing
5.5 Min/Max Mode
•
While in Normal Mode, press the MIN/MAX key to enter the maximum mode.
•
In the maximum reading Mode, press the + key to display the following maxi-
mum values together with the time and date stamp when these values were
recorded. Press SET key while the corresponding maximum value is displayed to
reset to the current reading together with the current time and date.
1.
Indoor humidity maximum
2.
Indoor temperature maximum
3.
Outdoor humidity maximum
4.
Outdoor temperature maximum
5.
Wind chill temperature maximum
6.
Dew point temperature maximum
7.
Pressure maximum
8.
Wind speed maximum
9.
Gust speed maximum
10. 1Hour rain maximum
11. 24 hour rain maximum
12. Week rainfall maximum
13. Month rainfall maximum
•
While in Normal Mode, press twice the MIN/MAX key to enter the minimum
mode.
•
In the minimum reading Mode, press the + key to display the following maxi-
mum values together with the time and date stamp when these values were
recorded. Press SET key while the corresponding minimum value is displayed to
reset to the current reading together with the current time and date.
1.
Indoor humidity minimum
2.
Indoor temperature minimum
3.
Outdoor humidity minimum
4.
Outdoor temperature minimum
5.
Wind chill temperature minimum
6.
Dew point temperature minimum
7.
Pressure minimum
28
24.01.2011
13:40 Uhr
Seite 15
STRATOS –
Wireless weather station
digit flashing
digit flashing
STRATOS –
Wireless weather station
6. Specifications
Transmission distance in open field:
Frequency:
Measuring interval
thermo-hygro sensor:
Alarm duration:
Temperature:
Measuring unit:
Measuring range:
outdoor:
indoor:
Resolution:
Accuracy:
Humidity
Measuring unit:
Measuring range:
Resolution:
Accuracy:
Rain volume
Measuring unit:
Rain volume display:
Resolution:
Wind speed
Measuring unit:
Wind speed :
Atmospheric pressure
Measuring unit:
Measuring range:
Resolution:
Accuracy:
Power consumption
Base station:
Remote sensor:
Battery life:
100 meter max.
868MHz
48 sec
120 sec
°C/°F
-40°...+65°C
-40°...+149°F
0°...+60°C
32°...+140°F
(show OFL if outside range)
0.1°C
±1°C
%RH
10%...99% RH
1%
±3% for 20...80% RH, otherwise ±5%
mm/inch
0 - 9999mm
0-393.6 inch
(show OFL if outside range)
0.3mm (if rain volume < 1000mm)
1mm (if rain volume > 1000mm)
km/h, m/s, mph, knots, Beaufort
0~180km/h / 0-50 m/s, 0-111.8 mph
(show OFL if outside range)
hPa / inHg
300hPa – 1100hPa
8.85 – 32.5inHg
0.1hPa
±3hPa
3 x AA 1.5V LR6 Alkaline batteries
2 x AA 1.5V LR6 Alkaline batteries
About 12 months for base station
About 24 months for thermo-hygro sensor
29